Caso Studio Refrigeratori per Trattamento Acque Reflue

Chiller per player internazionale dell'agroalimentare in Senegal

Lorem ispum dolor sit amet

  • Significantly reduced energy consumption >50%
  • Smaller & cheaper components low pressure system with increased reliability
  • Increased food quality due to more even temperature
Azienda
Multinazionale del trattamento acque reflue
Anno
2021/2022
Localizzazione
Veneto, Italia
Tipologia interlocutore
Impiantista
Campo di applicazione
Trattamento acque reflue
Storia in breve
L'azienda cliente è attiva da più di 150 anni. Si occupa di installazione impianti di trattamento e depurazione delle acque e di smatimento di rifiuti, producendo acqua potabile per più di 60milioni di persone nel mondo.
Elenco delle esigenze del cliente
N. 1 chiller a servizio dell'impianto di riuso dell'effluente civile.
N. 1 chiller a servizio del nuovo comparto ozono per adeguamento dell'impianto di trattamento terziario.
Tecnologie fornite
N. 2 refrigeratori per oli di processo RWE 624/4 ax-ST
Fluido e temperatura in uscita
Acqua/glicole 23°C
Aria ambiente
Max 40°C
Potenze richieste
1,2 MW

After a devastating fire Creta Farm decided to rebuild and install a cutting edge energy efficient solution for the production plant in Crete. The prestigious assignment to design the new cold storage went to ecoRef in Athens. They designed an indirect cooling system with R407F and Temper -15 as secondary fluid using adiabatic Mita technology. The results have exceeded the expectations with significantly reduced energy costs.

Rethymno Production plant

To comply with the new F-gas regulations and to reduce the energy consumption, Creta Farm and ecoRef installs a modern secondary refrigeration system with a high reliability.

The refrigeration installation

The old R22 compressors was in good condition and could be saved and used in the new installation. The new system was designed with R407F as the primary refrigerant and Temper -15 as heat transfer fluid.

The system is water-cooled via a high efficient Mita evaporative condenser which operates with adiabatic method. Aerodynamic type of fan blades are used which minimize energy input from the motors. The motors are directly coupled in the fans minimizing moving components (less maintenance). Mita electronic management system controls condensing temperature and pressure, by continuous calibration of fan speed and water consumption.

Due to the design of taking into consideration condensing pressure and outside temperature the system can run in dry mode, wet mode and mix mode(dry/wet) maximizing energy efficiency and minimizing water consumption.

A buffer tank of 8m3 stores Temper -15 at -6 °C and service the refrigerated areas through a set of electronically con-trolled pumps. The freezer circuit remained a R407F-DX system with electronic expansion valves and Energy Efficient Defrosting

After a devastating fire Creta Farm decided to rebuild and install a cutting edge energy efficient solution for the production plant in Crete. The prestigious assignment to design the new cold storage went to ecoRef in Athens. They designed an indirect cooling system with R407F and Temper -15 as secondary fluid using adiabatic Mita technology. The results have exceeded the expectations with significantly reduced energy costs.

Rethymno Production plant

To comply with the new F-gas regulations and to reduce the energy consumption, Creta Farm and ecoRef installs a modern secondary refrigeration system with a high reliability.

The refrigeration installation

The old R22 compressors was in good condition and could be saved and used in the new installation. The new system was designed with R407F as the primary refrigerant and Temper -15 as heat transfer fluid.

The system is water-cooled via a high efficient Mita evaporative condenser which operates with adiabatic method. Aerodynamic type of fan blades are used which minimize energy input from the motors. The motors are directly coupled in the fans minimizing moving components (less maintenance). Mita electronic management system controls condensing temperature and pressure, by continuous calibration of fan speed and water consumption.

Due to the design of taking into consideration condensing pressure and outside temperature the system can run in dry mode, wet mode and mix mode(dry/wet) maximizing energy efficiency and minimizing water consumption.

A buffer tank of 8m3 stores Temper -15 at -6 °C and service the refrigerated areas through a set of electronically con-trolled pumps. The freezer circuit remained a R407F-DX system with electronic expansion valves and Energy Efficient Defrosting

Idea icon

Vuoi una consulenza senza impegno?

Raccontaci il tuo progetto nella refrigerazione: avrai una soluzione basata sulle tue singole esigenze impiantistiche.

Contattaci ora

Alcune realizzazioni Frigofluid

Risparmio energetico con un impianto di refrigerazione chiavi in mano

Una grande azienda di lavorazione della plastica aveva necessità di rinnovare il proprio impianto di refrigerazione nella sua interezza. Durante la chiusura estiva ed il contestuale fermo produzione abbiamo realizzato un impianto di refrigerazione chiavi in mano completo di: refrigeratori, raffreddatori adiabatici, scambiatore, quadri elettrici e serbatoio di accumulo.